- All Products
- Cables, Wires - Management
- Protective Hoses, Solid Tubing, Sleeving
4,649
results
Compare | Image | Part No | Manufacturer | Description | Inventory | Pricing | Quantity | Series | Packaging | Part Status | Type | Type Attributes | Diameter - Inside | Diameter - Outside | Material | Color | Length | Wall Thickness | Operating Temperature | Heat Protection | Abrasion Protection | Liquid Protection | Environment Protection | Features | Material Flammability Rating |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr Part No.HCTE-1000-0-SP-CS7063Internal Code2447-480-7338480 | TE Connectivity Raychem Cable Protection |
HOSE CORRUGATED ETFE
| Get a Quote | - | Helical Convolex™ HCTE | Spool | Active | Wire Loom, Protective Hose | Convoluted, Corrugated | - | - | Ethylene Tetrafluoroethylene (ETFE), Irradiated | - | - | - | - | - | - | - | - | - | - | |||
HCTE-1000-0-SP-CS7063 | |||||||||||||||||||||||||
Mfr Part No.HCTE-1500-0-SP-CS7063Internal Code2447-480-7338485 | TE Connectivity Raychem Cable Protection |
HOSE CORRUGATED ETFE
| Get a Quote | - | Helical Convolex™ HCTE | Spool | Active | Wire Loom, Protective Hose | Convoluted, Corrugated | - | - | Ethylene Tetrafluoroethylene (ETFE), Irradiated | - | - | - | - | - | - | - | - | - | - | |||
HCTE-1500-0-SP-CS7063 | |||||||||||||||||||||||||
Mfr Part No.HCTE-1625-0-SP-CS7063Internal Code2447-480-7338487 | TE Connectivity Raychem Cable Protection |
HOSE CORRUGATED ETFE
| Get a Quote | - | Helical Convolex™ HCTE | Spool | Active | Wire Loom, Protective Hose | Convoluted, Corrugated | - | - | Ethylene Tetrafluoroethylene (ETFE), Irradiated | - | - | - | - | - | - | - | - | - | - | |||
HCTE-1625-0-SP-CS7063 | |||||||||||||||||||||||||
Mfr Part No.HCTE-1750-0-SP-CS7063Internal Code2447-480-7338489 | TE Connectivity Raychem Cable Protection |
HOSE CORRUGATED ETFE
| Get a Quote | - | Helical Convolex™ HCTE | Spool | Active | Wire Loom, Protective Hose | Convoluted, Corrugated | - | - | Ethylene Tetrafluoroethylene (ETFE), Irradiated | - | - | - | - | - | - | - | - | - | - | |||
HCTE-1750-0-SP-CS7063 | |||||||||||||||||||||||||
Mfr Part No.HCTE-2000-0-SP-CS7063Internal Code2447-480-7338491 | TE Connectivity Raychem Cable Protection |
HOSE CORRUGATED ETFE
| Get a Quote | - | Helical Convolex™ HCTE | Spool | Active | Wire Loom, Protective Hose | Convoluted, Corrugated | - | - | Ethylene Tetrafluoroethylene (ETFE), Irradiated | - | - | - | - | - | - | - | - | - | - | |||
HCTE-2000-0-SP-CS7063 | |||||||||||||||||||||||||
Mfr Part No.HE10x Protective metal hose (1,5m)Internal Code1077-480-7351868 | HAUBER Elektronik |
for HE10x - V4A (1.5 m)
| 6 Available |
|
Unit Price:
$173.6 Minimum: 1 Multiple: 1 | - | Retail Package | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
HE10x Protective metal hose (1,5m) | |||||||||||||||||||||||||
Mfr Part No.HE10x Protective metal hose (4.5 m)Internal Code1077-480-7351869 | HAUBER Elektronik |
for HE10x - V4A (4.5 m)
| 6 Available |
|
Unit Price:
$307.2 Minimum: 1 Multiple: 1 | - | Retail Package | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
HE10x Protective metal hose (4.5 m) | |||||||||||||||||||||||||
Mfr Part No.HPACC-17B.50Internal Code965-480-7426854 | Fraenkische USA, LP |
FIPLOCK, HD, PA6 MOD BS C, NW17,
| Get a Quote | - | Fiplock® | Bulk | Active | Wire Loom, Protective Hose | Convoluted, Corrugated | 0.634" (16.10mm) | 0.831" (21.10mm) | Polyamide (PA6), Nylon 6 | Black | 164' (50.00m) | - | -50°C ~ 105°C | - | - | - | Weather Resistant | - | - | |||
HPACC-17B.50 | |||||||||||||||||||||||||
Mfr Part No.HPAFC-48B.25Internal Code965-480-7426872 | Fraenkische USA, LP |
FIPLOCK, HD, PA6 MOD V0, NW 48,
| Get a Quote | - | Fiplock® | Bulk | Active | Wire Loom, Protective Hose | Convoluted, Corrugated | 1.839" (46.70mm) | 2.134" (54.20mm) | Polyamide (PA6), Nylon 6 | Black | 82.02' (25.00m) | - | -45°C ~ 120°C | Flame Retardant | - | - | Weather Resistant | - | UL94 V-0 | |||
HPAFC-48B.25 | |||||||||||||||||||||||||
Mfr Part No.HPDFC-29B.50Internal Code965-480-7428034 | Fraenkische USA, LP |
FIPLOCK, HD, PA12 MOD V0, NW29,
| Get a Quote | - | Fiplock® | Bulk | Active | Wire Loom, Protective Hose | Convoluted, Corrugated | 1.114" (28.30mm) | 1.366" (34.70mm) | Polyamide (PA12), Nylon 12 | Black | 164' (50.00m) | - | -50°C ~ 110°C | Flame Retardant | - | - | Weather Resistant | - | UL94 V-0 | |||
HPDFC-29B.50 | |||||||||||||||||||||||||
Mfr Part No.HPDFC-36B.25Internal Code965-480-7428035 | Fraenkische USA, LP |
FIPLOCK, HD, PA12 MOD V0, NW36,
| Get a Quote | - | Fiplock® | Bulk | Active | Wire Loom, Protective Hose | Convoluted, Corrugated | 1.409" (35.80mm) | 1.665" (42.30mm) | Polyamide (PA12), Nylon 12 | Black | 82.02' (25.00m) | - | -50°C ~ 110°C | Flame Retardant | - | - | Weather Resistant | - | UL94 V-0 | |||
HPDFC-36B.25 | |||||||||||||||||||||||||
Mfr Part No.HPDFF-10B.50Internal Code965-480-7428038 | Fraenkische USA, LP |
FIPLOCK, HD, PA12 MOD V0, NW10,
| Get a Quote | - | Fiplock® | Bulk | Active | Wire Loom, Protective Hose | Convoluted, Corrugated | 0.362" (9.20mm) | 0.504" (12.80mm) | Polyamide (PA12), Nylon 12 | Black | 164' (50.00m) | - | -50°C ~ 110°C | Flame Retardant | - | - | Weather Resistant | - | UL94 V-0 | |||
HPDFF-10B.50 | |||||||||||||||||||||||||
Mfr Part No.HPDSC-56B.25Internal Code965-480-7428047 | Fraenkische USA, LP |
FIPLOCK, HD, PA12 MOD BS, NW56,
| Get a Quote | - | Fiplock® | Bulk | Active | Wire Loom, Protective Hose | Convoluted, Corrugated | 2.217" (56.30mm) | 2.646" (67.20mm) | Polyamide (PA12), Nylon 12 | Black | 82.02' (25.00m) | - | -50°C ~ 110°C | - | - | - | Weather Resistant | - | - | |||
HPDSC-56B.25 | |||||||||||||||||||||||||
Mfr Part No.HPDSC-95B.10Internal Code965-480-7428049 | Fraenkische USA, LP |
FIPLOCK, HD, PA12 MOD BS, NW95,
| Get a Quote | - | Fiplock® | Bulk | Active | Wire Loom, Protective Hose | Convoluted, Corrugated | 3.594" (91.30mm) | 4.173" (106.00mm) | Polyamide (PA12), Nylon 12 | Black | 32.81' (10.00m) | - | -50°C ~ 110°C | - | - | - | Weather Resistant | - | - | |||
HPDSC-95B.10 | |||||||||||||||||||||||||
Mfr Part No.HPDSF-07B.50Internal Code965-480-7428050 | Fraenkische USA, LP |
FIPLOCK, HD, PA12 MOD BS, NW07,
| Get a Quote | - | Fiplock® | Bulk | Active | Wire Loom, Protective Hose | Convoluted, Corrugated | 0.244" (6.20mm) | 0.394" (10.00mm) | Polyamide (PA12), Nylon 12 | Black | 164' (50.00m) | - | -50°C ~ 110°C | - | - | - | Weather Resistant | - | - | |||
HPDSF-07B.50 | |||||||||||||||||||||||||
Mfr Part No.FIN0.25BK50Internal Code2457-480-6901187 | Techflex |
SLEEVING 0.250" ID FBRGLASS 50'
| 11 Available |
|
Unit Price:
$116.848 Minimum: 1 Multiple: 1 | FireFlex® | Spool | Active | Sleeving, Insulated | Braided | 0.250" (6.35mm) | 0.394" (10.00mm) | Fiberglass, Silicone Coated, Halogen Free | Black | 50.00' (15.24m) | 0.072" (1.83mm) | -54°C ~ 260°C | Flame Resistant, Heat Resistant | Abrasion and Cut Resistant, Puncture Resistant | Gasoline Resistant, Moisture Resistant | - | Chemical Resistant, Solvent Resistant | Non Flammable | ||
FIN0.25BK50 | |||||||||||||||||||||||||
Mfr Part No.FIN0.25RD50Internal Code2457-480-6901189 | Techflex |
SLEEVING 0.250" ID FBRGLASS 50'
| 23 Available |
|
Unit Price:
$87.648 Minimum: 1 Multiple: 1 | FireFlex® | Spool | Active | Sleeving, Insulated | Braided | 0.250" (6.35mm) | 0.394" (10.00mm) | Fiberglass, Silicone Coated, Halogen Free | Red | 50.00' (15.24m) | 0.072" (1.83mm) | -54°C ~ 260°C | Flame Resistant, Heat Resistant | Abrasion and Cut Resistant, Puncture Resistant | Gasoline Resistant, Moisture Resistant | - | Chemical Resistant, Solvent Resistant | Non Flammable | ||
FIN0.25RD50 | |||||||||||||||||||||||||
Mfr Part No.FIN0.38BK100Internal Code2457-480-6901190 | Techflex |
SLEEVING 0.375" ID FBRGLASS 100'
| Get a Quote | - | FireFlex® | Bag | Active | Sleeving, Insulated | Braided | 0.375" (9.52mm) | 0.519" (13.18mm) | Fiberglass, Silicone Coated, Halogen Free | Black | 100' (30.48m) | 0.072" (1.83mm) | -54°C ~ 260°C | Flame Resistant, Heat Resistant | Abrasion and Cut Resistant, Puncture Resistant | Gasoline Resistant, Moisture Resistant | - | Chemical Resistant, Solvent Resistant | Non Flammable | |||
FIN0.38BK100 | |||||||||||||||||||||||||
Mfr Part No.FIN0.38RD100Internal Code2457-480-6901191 | Techflex |
SLEEVING 0.375" ID FBRGLASS 100'
| Get a Quote | - | FireFlex® | Spool | Active | Sleeving, Insulated | Braided | 0.375" (9.52mm) | 0.519" (13.18mm) | Fiberglass, Silicone Coated, Halogen Free | Red | 100' (30.48m) | 0.072" (1.83mm) | -54°C ~ 260°C | Flame Resistant, Heat Resistant | Abrasion and Cut Resistant, Puncture Resistant | Gasoline Resistant, Moisture Resistant | - | Chemical Resistant, Solvent Resistant | Non Flammable | |||
FIN0.38RD100 | |||||||||||||||||||||||||
Mfr Part No.FIN0.50RD100Internal Code2457-480-6901194 | Techflex |
SLEEVING 0.5" ID FBRGLASS 100'
| Get a Quote | - | FireFlex® | Spool | Active | Sleeving, Insulated | Braided | 0.500" (12.70mm) | 0.644" (16.36mm) | Fiberglass, Silicone Coated, Halogen Free | Red | 100' (30.48m) | 0.072" (1.83mm) | -54°C ~ 260°C | Flame Resistant, Heat Resistant | Abrasion and Cut Resistant, Puncture Resistant | Gasoline Resistant, Moisture Resistant | - | Chemical Resistant, Solvent Resistant | Non Flammable | |||
FIN0.50RD100 |